Theory |
Rotary Pump |
Structure |
Screw Pump |
Usage |
Water |
Power |
Electric |
Standard or Nonstandard |
Standard |
Pressure |
Low Pressure |
Place of Origin |
Guangdong China (Mainland) |
Brand Name |
Kelips |
Model Number |
HM-1100A |
Detailed Product Description The use of Installation ,Notes 1, pumps for water, well water, boiler water use, such as rural farmland, farming, gardens, hotels, boilers, pressurized, canteens and high-rise buildings such as bottled water, water conditions for water transportation. Before using, put water inside , power will be able to be automatic, after tens of seconds later you do not need to use irrigater,and close the water pump, water pipes should be as short as possible and not allowed to leak, or no water absorption. 2, the pumps installed in wells as much as possible just above; but the pump can only be installed far away from the wells, the maximum length of pipe from the wells depends on the absorption process. Suction height of the dry season prevail Suction height(m)87654Horizontal length of pipes(m)314.52637.549 When the pump and wells installed together, easily sucked into the sand, pipe ends need to install the filter. Filters can be purchased at the pump sales. 3, pump dry running is strictly prohibited to avoid damage to seals, causing the pump does not work. 4, the pressure of gas filling the memory must be kept under pressure to switch almost.(Under such pressure switch almost 1.1kg, with almost 1.8kg, then the gas filling the memory is 1.1kg.) Operating 1, the water pump in the initial need to add a little water before the start, we must take it as the primary thing. 1) The opened mouth water cap, into the water 2) Cover with water port cap, open a faucet 3) Plug in the power operation of the pump, 3 to 8 minutes after the water would 4) If no water may be due to insufficient water, so to add water 2, open the faucet wide use, low power consumption, saving electricity. 3, the pump on hold for a long time before use Collapse in the dirt as solidification or adhesion, even turn on the switch, the motor may or may not turn, then, cut off the power, and then use a screwdriver or the like to the rear of the motor shaft rotation several times and used as usual. Failure causes and treatment measures TroubleshootingReasonTreatment measuresMotor does not turnMotor temperature too high or too much current, the protector automatically tripA: Wait for the motor cooling (20 to 30 minutes), the motor normal automatic operationB :After cooling, still running, for sale at the address pleaseBad wiringPlug inserted firmlyBreakRenewal lineMotor failureRepair or replace motorVoltage is too lowPlease solve the power companyStuck impellerCoagulum pump cover demolition and debris cleanupWater pressure too highWaiting for water pressure below the pressure after the presure switchMotor running without waterWell below the standard levelCheck the water level in wellsBlocked valve failure and water against the currentOpened the valve cover, valve and clear against the current waterAir into the suction pipeCheck the piping connection seal is intactFleeing into the air from the sealReplace with new sealBroken impellerReplacement impellerWater off the motor frequentlyNot parallel and out of waterAdjust the amount of waterDo not use water off the motor frequentlyPressure switch failureRepair or replacementPipe or pump water from the leakCheck the seal is intact leaksAgainst the current valve failureCleaning the valve against the currentAgainst the current valve leakage, water leakageCleaning, replace the valve or replace the equipment against the current water Contact us Tel: 8620-39952288 Mobile:15920396921 13826179696 Fax:8620-34827068Factory Add:163,Ying Bin lu,Nan Cun Town,Panyu District,Guangzhou ( besides Sha Ba Bi Ya Hotel)Website: http://www.gzkljx.cn http://guangzhoukeling.en.alibaba.com If you have any questions, please feel free to contact with us! warmly welcome to have a visit to our ware house or factory !